Test Criteria | Test content | Equipment to use |
---|
Insert/pull force test | Measure insert / pull force by repeatedly connecting rece and harness | Insert / pull force test machine |
Bending test | By repeatedly bending (with conductivity), measure bending frequency till failing | Cable bending test machine |
Twisting test | By repeatedly twisting (with conductivity), measure twisting frequency till failing | Cable twisting machine |
Pressure test | By putting pressure onto harness using sharp edge, measure pressure when cut | – |
Pull test | By pulling harness with connector fixed, measure force when cut | Digital push/pull gauge |
Vibration/impact test | By giving vibration or impact onto harness, measure contact resistance | Vibration test machine |
High / low temp test | After leaving harness in high/low temp environment, measure connection resistance | Homoiothermal & humidity testing tub machine (large and table size) |
High / low temp test | After leaving harness in high/low humidity cycle environment, measure insert/pull force and connection resistance | Homoiothermal & humidity testing tub machine (large and table size) |
High / low temp impact test | After leaving harness in high/low temp cycle environment, measure insert/pull force and connection resistance | High/low temp impact test machine |
Gas corrosion test | After spraying sulfur dioxide or hydrogen sulfide, measure connection resistance | Gas corrosion test machine |
Salt water spray test | After spraying salt water onto harness, measure connection resistance | Salt water spray test machine |